M O O N L I G H T

Loading

Salient Features

Home Salient Features
Table

Salient features:

Descriptions

Parameters

Project Name

Balephi-A Hydropower Project (BAHP)

Location

Latitude

27°50’48”N to 27°51’42”N

Longitude

85°45’00”E to 85°46’31”E

District

Sindhupalchok, Central Development Region

Village Development Committee        

Golche and Selang VDC

Type of power plant

Type

Run-off- the-river snow fed type

Hydrology

 

Catchment area at intake site

542.65 km

Design Discharge

 

32.40 m3/s

 

Probability of exceedance of Design Flow

40%

Design flood at intake (1 in 100 yrs)

2008.2 m3/s

Design flood at intake (1 in 200 yrs)

2363.5 m3/s

 

Diversion weir

 

Type

Ogee type diversion structure with bottom under sluice

Crest level

912 m

Length

33 m

Height

7 m above natural bed

Gate at undersluice

2 nos. of hydraulically operable gate

Intake

 

Type

Side intake fitted with 5 numbers of course track rack

Size of opening

5.1 m x 2.1 m clear opening 5 numbers

Intake invert level

909.80 m

Gravel Trap

 

Type

Concrete lined trapezoidal open chamber behind just after intake

Length

~18 m

Width

~16m

Height

10.5 m

Approach canal

 

Shape

Rectangular concrete lined box canal

Length

~82 m

Width

4.50 m

Height

3m

Bed slope

1:500

            Settling Basin

 

Type

Surface

No of basin

2

Nominal Size of Trapped Particle        

0.20 mm

Trap efficiency

90%

Size

Effective size: 107m (L)x22.5m(W)x 8.5 m(H)

Flushing

Gated Pipe, Dia 0.90m

Headrace canal

 

Shape

Rectangular concrete lined box canal

Length

~948 m

Width

4.70 m

Height

3.50m

Bed slope

1:1000

             Forbay

 

Type

Surface, concrete structure

Size

20m x 5.7m x 10.7m (Effective size)

 

           Headrace pipe

 

Type

Buried/Surface

Material

Steel pipe

Numbers

1

Diameter

3.8 m

Length

 2281 m

Surge Tank

 

Type

Circular, COncrete

Diameter

12.3m dia and 16m height

 Penstock Pipe

 

Type

Buried/Surface

Material

Steel pipe

Numbers

1

Diameter

3.8 m

Length

803  m

Thickness

12 mm to 22mm

Powerhouse

 

Type

Surface

Size

55m (L) x 18m (W) x 14.81m

Gross head

86 m

Net head

(81m)

Design flow

32.40 m3/s

Capacity

22.14 MW

Tailrace canal

 

Level at just after powerhouse (NTWL)

826m

Shape 

Rectangular but covered type

Length

~115 m

Cross-sectional area

5m wide X 2 m depth 

Bed slope

1:200

Turbines

 

Type

Francis

No of units

3 Nos.  (each of 7.38 MW capacity)

Rated Speed

750rpm

Generators

 

Type

Brushless Synchronous

Capacity

7.68 MVA

Voltage

11 kV

Transmission line

 

Voltage

33kV

Length

~2 Km

Connection

9 km long 33KV double circuit to Pangtang sub station

Transformer

 

Type

Three phase, out door

No of unit

2

Power factor

0.8

Voltage ratio

6.6/33

Frequency

50 Hz

Energy generation

 

Mean annual energy per year

125.3 GWh

Dry energy

37.4 GWh

Wet energy

87.9 GWh

Access road

~ 7 Km up-gradation is required from Balephi bazaar to naubise.

Length

~ 10 km long track opening from Naubise to kumeshwor.

Type

Gravel road, single lane.

Construction period

 

Construction period from award of civil contract, yrs

3

Economic Indicators

Project cost, MNRs

4863

Construction cost, MNRs

3850.5

Construction cost per kW, MNRs

219.6

Internal Rate of Return (FIRR), %

12.08

B/C ratio at discount rate of 10%

1.03

Payback period, yrs

12